Customization: | Available |
---|---|
After-sales Service: | 7*24 Hours |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 5355/Pcs
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
3nh New Economic Benchtop Spectrophotometer TS8503 Open Transmission Bin Testing Machine
The desktop spectrophotometer TS8503 is a high-precision colorimeter developed and upgraded by 3nh using its own core technology. It is suitable for diversified color management of various opaque, transparent, translucent and fluorescent samples. It is widely used in industries such as plastic electronics, chemical coatings, ink printing, textile printing and dyeing, automotive electronics, medical analysis, cosmetics and food analysis, as well as scientific research institutions, laboratory drug analysis and other fields.
Features:
1. High-performance dual-array image sensor
The high-sensitivity dual-array CMOS image sensor can achieve high-precision and high-repeatability measurements in a wide spectral response range.
2. Comprehensive measurement functions
It adopts the internationally widely applicable D/8 and D/0 dual optical path structure, supports SCI/SCE (including mirror reflection/excluding mirror reflection) measurement, supports reflection/transmission measurement, and is suitable for diversified color management of various opaque, transparent, translucent and fluorescent samples.
3. Combined LED light source + UV light source
It adopts a combination of full-spectrum LED light source + UV light source, covering the wavelength range of 360 to 780nm, including UV, 400nm cut-off light source, 420nm cut-off light source, 460nm cut-off light source, with sufficient spectral distribution, making UV testing more professional and significantly improving the reliability of measurement. sex.
4. Multi-posture measurement
Supports multi-posture placement measurement such as side measurement, upward measurement, downward measurement (optional inverted bracket), etc., which greatly improves the convenience and flexibility of measurement.
5. Open transmission bin
The open transmission bin is equipped to meet more sample testing needs, and even large-sized samples can be easily measured.
6. Automatic recognition of aperture switching
Equipped with four apertures: 25.4mm/15mm/8mm/4mm, users can configure the aperture and lens position according to their needs, taking into account special measurement needs, which is smart and convenient.
7. Rich color index
In addition to the commonly used color index measurement, it can also provide color indexes such as haze, transmittance, petroleum color scale (ASTM D1500), yellowness, whiteness, platinum cobalt index, Gardner index, Saybolt index, blackness, hue, etc. to meet the needs of diverse industries.
8. Real-time camera locating
The built-in camera real-time locating positioning can accurately determine whether the measured part of the object is the target center through the real-time camera locating, which improves the measurement efficiency and accuracy.
9. Excellent repeatability and inter-device difference
Repeatability ΔE*ab≤0.018, inter-device difference ΔE*ab≤0.24, ensuring the consistency of measurement data of multiple devices and facilitating sample data transfer between partners.
10. Independent light source detector
The instrument uses an independent light source detector, which can monitor the changes of light source at all times, ensuring the reliability of light source and test data.
11. Rigorous and pragmatic humanized design
The damping clamp is used to protect the sample being tested, and the spring-closed drawer is convenient for storing accessories or small samples.
12. Combined with color management software to achieve various extended functions
Combined with SQCX quality management software, it is suitable for quality monitoring and color data management in various industries. It can digitize the user's color management, compare color differences, generate test reports, provide multiple color space measurement data, and customize the customer's color management work.
Model | TS8503(LED) |
Optical Geometry | Reflect: D/8(diffused illumination, 8-degree viewing angle) ; |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; | |
Transmittance: D/0 (diffuse illumination: 0° viewing) ; | |
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source ; | |
HAZE (ASTM D1003); | |
Standards meet: CIE No.15, GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7,JIS Z8722 under condition C | |
Characteristic | 1. It is used for accurate analysis and transmission of laboratory color. Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control. |
2. 10.5 inch rotatable display pad, 128G storage, camera locating | |
3. Instrument can be measured on the side, upward measurement, and the downward measurement (use accessories) and other gestures. | |
4. Open transmission warehouse, available thickness of 54mm transmitted samples. | |
5. Automatic temperature and humidity compensation function. | |
Integrating Sphere Size | Φ154mm |
Light Source Device | 360nm-780nm Wavelength range ,combined LED Light. Including UV, 400nm cut-off light source, 420nmCut-off light source,360~780nm |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360~780nm |
Wavelength Interval | 10nm |
Semiband Width | 5nm |
Measured Reflectance Range | 0~200% |
Reflectivity Resolution | 0.01 |
Measuring Aperture | Reflective: |
XLAV Φ25.4mm/Φ30mm, LAVΦ15mm/Φ18mm , MAVΦ8mm/Φ10mm, SAVΦ4mm/Φ6mm | |
Transmissive: | |
Φ25.4mm(No limit on sample height and width, but thickness≤54mm) | |
Remark: | |
1. Automatic identification of aperture switch | |
2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE / Transmittance: SCI&SCE |
Color Space | CIE LAB,XYZ,Yxy,LCh,CIE LUV,Musell,s-RGB,HunterLab,βxy,DIN Lab99 |
Color Difference Formula | ΔE*ab,ΔE*uv,ΔE*94,ΔE*cmc(2:1),ΔE*cmc(1:1),ΔE*00, DINΔE99,ΔE(Hunter) ,ΔE*CH,555 Index |
Other Colorimetric Index | WI(ASTM E313,CIE/ISO,AATCC,Hunter,Taube,Berger Stensby) |
YI(ASTM D1925,ASTM 313),ISO brightness,R457 | |
MI (Metamerism Index), | |
Staining Fastness, Color Fastness, Color Strength, Opacity, | |
APHA/Hazen/Pt-Co Index,Gardner Index | |
8° Gloss,555 Index, Haze,Transmission(ASTM D1003), Saybolt index, ASTM D1500 Color code,carbon(My,dM), Color density CMYK(A,T,E,M), Tint,Color density(part function achieved via software in PC) | |
Observer Angle | 2°/10° |
Illuminant | D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,DLF,TL83,TL84,TPL5,U30,B,U35,NBF |
ID50,ID65,LED-B1,LED-B2,LED-B3,LED-B4,LED-B5,LED-BH1,LED-RGB1,LED-V1,LED-V2,LED-C2,LED-C3,LED-C5, customized light source(41 light sources in total,part achieved via software in PC) | |
Displayed Data | Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset, Color assessment, haze, liquid chromaticity |
Measuring Time | 2.0s(Measure SCI & SCE meantime about 4s ) |
Repeatability | Reflectance chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration); |
spectrum reflectance /transmission:≤0.1% | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.24 (Average for 12 BCRA Series II color tiles) |
Dimension | L*W*H=440x248x283mm |
Weight | Approx. 13.5kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 10.5-inch rotatable display pad |
Data Port | USB & Bluetooth |
Data Storage | 64G storage,above 100000pcs |
Language | Simplified Chinese, Traditional Chinese, English,(Optional Customized German,Russian, French ,Spanish ,Japanese, Thai, Korean, Polish, Portuguese) |
Operating Environment | 0~40ºC(32~104°F) |
Storage Environment | -20~50ºC(-4~122°F) |
Standard Accessory | Power Adapter, User Guide, U Disk(PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 15 caliber, 8 caliber, 4 caliber,Transmissive Test Component, cuvette, 10.5-inch screen |
Optional Accessory | Micro Aperture(4mm) transmission test clamp component, Instrument inversion components,culture dish,Film fixture |
Notes | Test reports can be printed through a network printer connected to a PC or display pad; The specifications are subject to change without notice. |