3nh Handhald Colorimeter St10 Color testing equipment to Replace Cr-10 Plus Chroma Meter
ST10 is a new portable spectrocolorimeter with 3nh own core research and development technology. It is easy to use and can be measured with one click. It uses a built-in large area silicon photodiode array sensor. It has excellent repeatability and inter-station difference, the measured data are steady, accurate and reliable. ST10 spectrocolorimeter with Φ8MM/φ10mm platform measuring aperture, in plastic electronics, paint coating, textile printing and dyeing, printing paper products, automotive, medical, cosmetics and food industries, scientific research institutions, laboratories are widely used.
Product name | ST10 spectrocolorimeter | |
Optical Geometry | D/8(diffused illumination, 8-degree viewing angle) | |
Specular Component | SCI Including the specular reflection of light | |
Meet The Criteria | CIE NO.15,GB/T 3978,GB 2893,GB/T 18833,ISO7724-1,ASTM E1164,DIN5033 Teil7 | |
Repeatability* | ΔE*ab≤0.05 | |
Inter-instrument Error** | ΔE*ab≤0.4 | |
Displayed Accuracy | 0.01 | |
Measuring/Illuminating Aperture |
|
|
Measurement Indicators | Spectral reflectivity, CIE-Lab, CIE-LCh, HunteLab, CIE-Luv, XYZ, Yxy, RGB, chromatic aberration (ΔE * ab, ΔE * CMC, ΔE * 94, ΔE * 00) , whiteness (ASTM E313-00, ASTM E313-73, CIE/ISO, AATCC, Hunter, Taube Berger Stensby) , yellows (ASTM D1925, ASTM E313-00, ASTM E313-73) ,staining fastness, color-changing fastness, etc. (some of the indicators were achieved by PC) | |
Illuminant | D65,A,C,D50,F2,F7,F11 | |
Displayed Data | Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Simulation, Color Offset | |
Light Source | Combined full spectrum LED light source | |
Locating Method | Stability film, visual | |
Calibration | Intelligent automatic calibration (Contact Type) | |
Observer Angle | 2°,10° | |
Integrating Sphere Size | 40mm | |
Spectrophotometric Mode | Flat Grating | |
Sensors | Large-area silicon photodiode array ( double-row 20 group) | |
Wavelength Interval | 10nm | |
Wavelength Range | 400-700mm | |
Measured Reflectance Range | 0-200% | |
Reflectivity resolution | 0.01% | |
Measurement Mode | Single Measurement, Average Measurement(2-99times) | |
Measuring Time | About 1s | |
Size | L * W * H=114 X 70 X 208mm | |
Weight | About 435g(Calibration block not included) | |
Battery | Li-ion battery, 8500 measurements within 8 hours | |
Illuminant Life Span | 10 years, more than 1.5 million times measurements | |
Display | 3.5-inch TFT color LCD, Capacitive Touch Screen | |
Data Port | USB | |
Data Shorage | Standard 500 Pcs, Sample 10000 Pcs, Mass storage on PC side | |
Software Support | Windows | |
Language | Simplified Chinese, English, Traditional Chinese | |
Operating Environment | 0~40ºC, 0~85%RH (no condensing), Altitude < 2000m | |
Storage Environment | -20~50ºC, 0~85%RH (no condensing) | |
Standard Accessory | Power Adapter, USB Cable, User Guide, PC Software(Download from office website), White and Black Calibration Cavity, Protective Cover, Wrist strap, 8mm flat aperture, 4mm tip aperture | |
Optional Accessory | USB Micro Printer, Powder Test Box | |
Notes: * 30 standard deviations of the whiteboard were measured at a 5-second interval after whiteboard calibration; ** BCRA Series II 12-panel measurement average; *** The illumination aperture is the actual aperture size of the instrument; If there are any changes to the above parameters, without prior notice. |
Application Industry
3nh colorimeter and spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
1. Can 3nh Benchtop spectrophotometer be equivalent to any models of world famous brand?
Answer: Yes, they are equivalent to CM-3700A of KONICA MINOLTA and Ci7800 of X-rite and Datacolor 800.
2. Are you a trader or a manufacturer?
Answer: We 3nh is a manufacturer. We research and develop, design and produce, market and sell color measuring instruments and gloss meters.
Our company office, together with our factory are located in Shenzhen which is famous for manufacturing. Welcome to visit us!
3. What's your main market?
Answer: We sell to the global market.
4. How long is your delivery time?
Answer: Generally, it is 1-3 working days after the payment confirmed.
5. What is your payment terms?
Answer: The payment term is 100% T/T in advance. The first suggested payment method is via made-in-China platform here.
6. What's your minimum order quantity (MOQ)?
Answer: Our MOQ is 1 set. If you order more than 3 sets, we can provide discount.