Customization: | Available |
---|---|
After-sales Service: | 1 Year |
Warranty: | 1 Year |
Still deciding? Get samples of US$ 1470/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
YH1102 haze meter can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test.Open sample bin can be vertically and horizontally tested to accommodate more samples to be tested.The YH1102 haze meter uses a PD array detector to meet the CIE V(λ)2 degree visual response. The compensation method can be used to measure the light transmittance and haze with high precision and repeatability.
Application
YH1102 haze meter is widely used in glass processing, plastic processing, film processing, screen processing, packaging industry, liquid pharmaceutical analysis and other aspects.
Technical Specification
Product Model | YH1102 Haze Meter |
Optical Geometry | Transmittance:0/D(Parallel light illumination, diffuse viewing);Conform to the standards:ASTM D1003/1044, ISO 14782,GB/T 2410, JJF 1303-2011,CIE 15.2,JIS K7105,JIS K7361,JIS K 7136 |
Characteristic | The instrument can easily achieve ASTM D1003 non-compensation method, full light transmittance, haze test. Open measuring area for vertical and horizontal testing. In glass processing, plastic processing, film, screen processing, packaging and other industries are widely used in transmittance,haze detection. |
Integrating Sphere Size | Φ154mm |
Light Source | 400nm to 700nm, combined LED light |
Spectrophotometric Mode | / |
Sensor | The PD array detector, satisfies CIE V(λ)2 degree visual response |
Wavelength Range | / |
Wavelength Interval | / |
Semiband Width | / |
Measurement range | 0~100% |
Measuring Aperture | Φ20mm/Φ8mm(Dual Aperture) |
Sample Size | Thickness <170mm |
Color Space | / |
Color Difference Formula | / |
Other Colorimetric Index | Haze(ASTM D1003/1044),Transmittance T(ASTM) |
Observer Angle | 2° |
Illuminant | D65,A,C |
Displayed Data | PASS/FAIL Result |
Measuring Time | About1.5s |
Resolution | 0.01unit |
Repeatability | Φ20mm,within 0.05(After preheating and calibration of the instrument, standard deviation values of standard haze tablets with a test haze of about 30 for 30 times were taken at intervals of 5s.) |
Inter-instrument Error | Φ20mm,with 0.4(After the instrument is preheated and calibrated, the standard deviation between the standard haze tablet and the reference value is tested at an interval of 5s.) |
Dimension | L*W*H=290X211X511mm |
Weight | About7.6kg |
Power | AC 24V, 3A Power adapter power supply |
Illuminant Life Span | 5 years, more than 3 million times measurements |
Display | 7-inch TFT color LCD, Capacitive Touch Screen |
Data Port | USB, Print serial port |
Data Storage | Standard 1000 pcs,sample 20000 pcs |
Language | Simplified Chinese,Traditional Chinese,English |
Operating Environment | 0~40ºC(32~104°F) |
Storage Environment | -20~50ºC(-4~122°F) |
Standard Accessory | Power Adapter, User Guide,Quality Management Software (download from the official website),USB cable,0% calibration box, measuring aperture. |
Optional Accessory | Micro-printer,Test fixture, standard haze sheet, foot switch |
Note: | The specifications are subject to change without notice. |